World's Largest Resource for Cardiovascular Perfusion

Perfusion NewswireMain ZoneTrainees Can Learn Minimally Invasive Aortic Valve Replacement Without Compromising Safety

Trainees Can Learn Minimally Invasive Aortic Valve Replacement Without Compromising Safety

OBJECTIVES: 

Minimally invasive aortic valve replacement (MiniAVR) is a technically advanced procedure. However, it results in equivalent operative mortality, less bleeding and reduced intensive care/hospital stay when compared with conventional AVR. Our aim was to assess the impact of trainee performance on short-term outcomes of patients undergoing elective and urgent MiniAVR where a significant proportion were performed by trainees.

METHODS: 

All patients undergoing non-emergency, elective and urgent, isolated MiniAVR between September 2005 and December 2012 were studied. Operative details and short-term outcomes, with particular attention to trainee performance, were analysed.

RESULTS: 

During the study period, there were 205 MiniAVR with a median age of 67 years (range 29-86); 74 (36%) operations were performed by trainees. The overall median cross-clamp and bypass times were 42 (range 33-63) and 59 min (range 59-94) for the attending surgeon and 52 (range 42-63) and 71 min (range 59-94) for the trainee (P = 0.03). Five MiniAVR patients (2.4%) required conversion to full sternotomy for ascending aortic replacement, right ventricular bleeding, coronary artery bypass graft surgery and failure to cardiovert. None of these cases were performed by trainees. Median lengths of intensive care and hospital stay were 1 and 5 days and were not different for attending surgeon and trainee. Only 1 (0.5%) patient died in hospital.

CONCLUSIONS: 

MiniAVR can be performed with a low conversion rate and hospital stay and taught to trainees without compromising safety.


Leave a Reply