Intercompartmental Fluid Volume Shifts During Cardiopulmonary Bypass Measured by A-Mode Ultrasonography
Abstract:
To investigate the time course of fluid extravasation during cardiopulmonary bypass (CPB), we measured the peripheral tissue thickness (TT) by A-mode ultrasound in 34 patients undergoing elective cardiac surgery. TT of the forehead was determined by a handheld A-mode ultrasound device and 10 MHz Transducer at nine defined intervals, from the night before surgery until the first postoperative day.
Dehydration due to fasting and the marked interstitial fluid extravasation during CPB could be detected by the changes of the peripheral TT. We conclude that parts of the fluid load during CPB are shifted from the intravascular compartment to the interstitial space in a time-dependent manner.