The adjustable PAB was found to improve early survival and also made delayed repair feasible in a better clinical state, with reduced mortality and morbidity.
There is significant increased risk of bleeding with peripheral VA cannulation of obese patients with BMI > 35. Cannulating surgeon should be aware of this bleeding risk in morbidly obese patient who undergo VA ECMO.