Comparison of Epsilon Aminocaproic Acid and Tranexamic Acid in Thoracic Aortic Surgery: Clinical Efficacy and Safety
OBJECTIVE:
To evaluate the efficacy and safety of tranexamic acid (TXA) versus epsilon aminocaproic acid (EACA) in patients undergoing thoracicaortic surgery.
DESIGN:
A prospective randomized study.
SETTING:
A tertiary care center.
PARTICIPANT:
The study was conducted on 64 consecutive adult patients undergoing thoracic aortic surgery with cardiopulmonary bypass (CPB).
INTERVENTIONS:
Group EACA received a bolus of 50 mg/kg of EACA after induction of anesthesia over 20 minutes followed by maintenance infusion of 25 mg/kg/h until chest closure. Group TXA received a bolus of 10 mg/kg of TXA after induction of anesthesia over 20 minutes followed by maintenance infusion of 1 mg/kg/h until chest closure.
MEASUREMENTS AND MAIN RESULTS:
Cumulated mean blood loss, total packed red blood cells, and blood product requirement up to 24 h postoperatively were comparable between groups. A significant renal injury (EACA 40% v TXA 16%; p = 0.04) and increased tendency for renal failure (EACA 10% v TXA 0%, p = 0.11; relative risk 2.15) were observed with EACA compared to TXA. There was increased tendency of seizure with TXA (EACA v TXA: 3.3% v 10%; p>0.05, relative risk 1.53). There was significant increase in the D-dimer from preoperative to postoperative values in Group EACA. (p< 0.01).
CONCLUSIONS:
Both EACA and TXA were equally effective in reducing the perioperative blood loss and transfusion requirement in patients undergoing thoracic aortic surgery. While significant renal injury was observed with EACA, there was a tendency for higher incidence of seizure with TXA. Prospective placebo-controlled trials recruiting larger sample size using sensitive biomarkers are required before any recommendations.