Blood Trauma Testing of CentriMag and RotaFlow Centrifugal Flow Devices: A Pilot Study
In this feasibility study, the blood trauma performance of the RotaFlow was similar or better than the CentriMag device under clinically equivalent, worst-case test conditions. The RotaFlow device may be a more cost-effective alternative to the CentriMag.
First Experience with the Ultra Compact Mobile Extracorporeal Membrane Oxygenation System Cardiohelp in Interhospital Transport
In patients with severe cardiopulmonary failure extracorporeal assist devices are to support patients during resuscitation, for transportation, until organ recovery, and as bridge to further therapeutic modalities.
Use of Methylene Blue in the Treatment of Refractory Vasodilatory Shock After Cardiac Assist Device Implantation: Report of Four Consecutive Cases
Vasodilatory shock frequently occurs after cardiac surgery, particularly after cardiac assist device implantation.
The RECOVER I: A Multicenter Prospective Study of Impella 5.0/LD for Postcardiotomy Circulatory Support
The use of the Impella 5.0/left direct device is safe and feasible in patients presenting with postcardiotomy cardiogenic shock.
Prospective Trial of a Pediatric Ventricular Assist Device
Options for mechanical circulatory support as a bridge to heart transplantation in children with severe heart failure are limited. We conducted a prospective, single-group trial of a ventricular assist device designed specifically for children as a bridge to heart transplantation.
Evaluation of Changes in Quality of Life Among Turkish Patients Undergoing Ventricular Assist Device Implantation
In this study we evaluated the effect of VAD implantation upon the quality of life among Turkish patients with end-stage heart failure.
Residual Blood Processing by Centrifugation, Cell Salvage or Ultrafiltration in Cardiac Surgery: Effects on Clinical Hemostatic and Ex-vivo Rheological Parameters
The study compared the effects of three blood concentration techniques after cardiopulmonary bypass on clinical hemostatic and ex-vivo rheological parameters.
Conventional Aortic Valve Replacement in Transcatheter Aortic Valve Implantation Candidates: A 5-Year Experience
Patient selection for transcatheter aortic valve implantation (TAVI) remains highly controversial. Some screened patients subsequently undergo conventional aortic valve replacement (AVR) because they are unsuitable TAVI candidates. This study examined the indications and outcomes for these patients, thereby determining the efficacy of the screening process.
Comparison of the Effects of Three Cell Saver Devices on Erythrocyte Function During Cardiopulmonary Bypass Procedure-A Pilot Study
The purpose of this study was to evaluate three commercially available cell saver (CS) devices in terms of erythrocyte function and the quality of washed RBCs during cardiopulmonary bypass (CPB).
Thoratec Centrimag Console
The Levitronix / Thoratec CentriMag short-term LVAS comprises a single-use centrifugal pump, a motor, and a primary drive console. Compared to other […]
Sechrist 3500 Air / Oxygen Mixer
The SECHRIST Air-Oxygen Mixer is a precision pressure regulation and proportioning device which is designed to accurately mix Medical Breathing Air and Medical Breathing Oxygen to any selected FIO2 between .21 and 1.0, for delivery to a variety of respiratory care equipment. Excellent condition.
Dideco Compact Advanced Autotransfusion System
The Dideco Compact A (Advanced) is a compact, portable autotransfusion system which utilizes a Latham bowl.