Qualitative Analysis of Batch Preparing Cryopreserved Fresh Platelet Rich Plasma
Cryopreservation can prevent lactic acid accumulation, pH reduce and activation of GPIIb/IIIa. (3) The membrane of partial platelets are affected by freezing and thawing.
Acute Renal Failure After Cardiopulmonary Bypass Surgery
Prevention of this disastrous complication appears to be better than treatment once it is fully established. However newer aggressive forms of early renal replacement/transplant therapies may have some promise.
Role of Protein Kinase C- (PKC) in Isoflurane-Induced Cardioprotection
Although isoflurane preconditioning resulted in a reduction in infarct size at all concentrations used, the protection was mediated by phosphorylation and translocation of PKC only at 0.4 MAC.
Platelet Gel Billing Summary
Currently the only way to be reimbursed for Autologous Platelet Rich Plasma for chronic non-healing wounds by Medicare is through a CMS approved clinical trial.
Total Arterial Revascularisation: Effect of Avoiding Cardiopulmonary Bypass on In-Hospital Mortality and Morbidity in a Propensity-Matched Cohort
Off-pump coronary surgery with complete arterial revascularisation can significantly reduce in-hospital morbidity and lengths of stay compared to conventional on-pump coronary surgery.
Hemodynamic Changes During Posterior Vessel Off-Pump Coronary Artery Bypass: Comparison Between Deep Pericardial Sutures and Vacuum-Assisted Apical Suction Device
Displacement of the heart using either a deep pericardial suture technique or a vacuum-assisted apical suction device caused a significant decrease in SVI. The hemodynamic changes during OM grafting were smaller when using a vacuum-assisted apical suction device.
Hemodynamic Changes During Posterior Vessel Off-Pump Coronary Artery Bypass: Comparison Between Deep Pericardial Sutures and Vacuum-Assisted Apical Suction Device
Displacement of the heart using either a deep pericardial suture technique or a vacuum-assisted apical suction device caused a significant decrease in SVI. The hemodynamic changes during OM grafting were smaller when using a vacuum-assisted apical suction device.
Left Ventricular Assist Device Performance With Long-Term Circulatory Support: Lessons From the REMATCH Trial
Despite the observed rates of device malfunction and replacement, LVAD implantation confers clinically significant improvement with regard to survival as compared with medical management.
Flow in Coronary Bypass Conduits On-Pump and Off-Pump
There were no major differences in conduit flow on-pump versus off-pump. Conventional coronary artery bypass grafting on-pump may restore up to approximately half of the normal resting coronary artery blood flow (250 mL/min).
Left Ventricular Assist Device Performance With Long-Term Circulatory Support: Lessons From the REMATCH Trial
Despite the observed rates of device malfunction and replacement, LVAD implantation confers clinically significant improvement with regard to survival as compared with medical management.
The ‘Gray Area’ of Malpractice Risk Management Keeps Problems from Becoming Lawsuits
Every medical practice should consider forming its own CRC as a way of actively managing liability risks. The payoff in terms of reduced tort claims, improved practice reputation, and regulatory compliance is incalculable.
AmSECT Today Newsletter (December 2004)