Use of the CDI Blood Parameter Monitoring System 500 for Continuous Blood Gas Measurement During Extracorporeal Membrane Oxygenation Simulation
The purpose of this experiment was to compare the Opticath and the CDI 500 in trending venous blood saturation during a simulation of ECMO.
The Future of the Perfusion Record: Automated Data Collection vs. Manual Recording
This study highlights the limitation of spot recording of perfusion events in the overall record keeping for perfusion management.
2004 Survey of ECMO in the Neonate After Open Heart Surgery: Circuitry and Team Roles
These data suggest that previously published ELSO-centric ECMO studies may significantly underestimate the contemporary application of modern technologies and the involvement of perfusionists.
Sensitivity of a Modified ACT Test to Levels of Bivalirudin Used During Cardiac Surgery
After Ethics Committee approval, a pilot study was performed to evaluate the feasibility of using bivalirudin for on-pump cardiac surgery and to evaluate dosing of bivalirudin in terms of the pharmacokinetic and safety profile in patients undergoing coronary artery bypass graft (CABG) surgery.
Use of the CDI Blood Parameter Monitoring System 500 for Continuous Blood Gas Measurement During Extracorporeal Membrane Oxygenation Simulation
The purpose of this experiment was to compare the Opticath and the CDI 500 in trending venous blood saturation during a simulation of ECMO.
Second Generation of Minimal Invasive Extracorporeal Circuit: Pilot Study Resting Heart System
Cardiopulmonary bypass (CPB) has evolved from a complex multifunctional system to the minimally invasive extracorporeal circuit (MIEC).
A sSngle Nucleotide Polymorphism of Macrophage Migration Inhibitory Factor is Related to Inflammatory Response in Coronary Bypass Surgery Using Cardiopulmonary Bypass
Here we analyzed genotype distribution and allele frequency of the MIF-173*G/C single nucleotide polymorphism (SNP) and MIF plasma levels in patients undergoing surgical revascularization with (on-pump, n=45) and without (off-pump, n=34) cardiopulmonary bypass (CPB).
SMART Tubing Presents an Increased Risk of Disconnection During Extracorporeal Circulation
In this study, we examined the in vitro mechanical ability of random samples (n = 10) of SMART and standard PVC tubing to withstand axial tension when the tubing was placed over a single barb of a connector.
The Future of the Perfusion Record: Automated Data Collection vs. Manual Recording
This study highlights the limitation of spot recording of perfusion events in the overall record keeping for perfusion management.
The Future of the Perfusion Record: Automated Data Collection vs. Manual Recording
This study highlights the limitation of spot recording of perfusion events in the overall record keeping for perfusion management.
Use of the CDI Blood Parameter Monitoring System 500 for Continuous Blood Gas Measurement During Extracorporeal Membrane Oxygenation Simulation
The purpose of this experiment was to compare the Opticath and the CDI 500 in trending venous blood saturation during a simulation of ECMO.
Lower Limits of Hematocrit and Mixed Venous Oxygen Saturation Ensuring Sufficient Cerebral Oxygenation During Hemodilution in Rabbits
This study was performed to identify critical values for these variables that would be able to ensure sufficient jugular venous oxygen saturation (SjO2), which reflects global cerebral oxygenation.