Clinical Evaluation of Poly(2-Methoxyethylacrylate) in Primary Coronary Artery Bypass Grafting
Poly(2-methoxyethylacrylate) (PMEA, X-coating) is a new polymer coating used in the ECC.
Is Platelet Function as Measured by Thrombelastograph Monitoring in Whole Blood Affected by Platelet Inhibitors?
Platelet inhibitors, especially the glycoprotein (GP) IIb/IIIa receptor antagonists, have demonstrated their effectiveness in reducing the acute ischemic complications of percutaneous coronary intervention (PCI) and in improving clinical outcomes in patients with acute coronary crisis.
Rat Cardiopulmonary Bypass Model: Application of a Miniature Extracorporeal Circuit Composed of Asanguinous Prime
A clinically relevant rat cardiopulmonary bypass (CPB) model would be a valuable tool for investigating pathophysiological and therapeutic strategies on bypass.
Is Platelet Function as Measured by Thrombelastograph Monitoring in Whole Blood Affected by Platelet Inhibitors?
Platelet inhibitors, especially the glycoprotein (GP) IIb/IIIa receptor antagonists, have demonstrated their effectiveness in reducing the acute ischemic complications of percutaneous coronary intervention (PCI) and in improving clinical outcomes in patients with acute coronary crisis.
Temperature Inaccuracies During Cardiopulmonary Bypass
The purpose of this study was to determine the accuracy of the coupled temperature measurement system and the CDI 500 arterial temperature sensor.
Clinical Evaluation of Poly(2-Methoxyethylacrylate) in Primary Coronary Artery Bypass Grafting
Poly(2-methoxyethylacrylate) (PMEA, X-coating) is a new polymer coating used in the ECC.
Accuracy of Temperature Measurement in the Cardiopulmonary Bypass Circuit
The aim of this study was to evaluate the accuracy of the temperature thermistors used in the Terumo Capiox SX25 oxygenator and to compare the temperature measured at the outlet of the oxygenator using the Capiox CX*TL Luer Thermistor with temperatures measured at distal sites.
Is Platelet Function as Measured by Thrombelastograph Monitoring in Whole Blood Affected by Platelet Inhibitors?
Platelet inhibitors, especially the glycoprotein (GP) IIb/IIIa receptor antagonists, have demonstrated their effectiveness in reducing the acute ischemic complications of percutaneous coronary intervention (PCI) and in improving clinical outcomes in patients with acute coronary crisis.
Temperature Inaccuracies During Cardiopulmonary Bypass
The purpose of this study was to determine the accuracy of the coupled temperature measurement system and the CDI 500 arterial temperature sensor.
Accuracy of Temperature Measurement in the Cardiopulmonary Bypass Circuit
The aim of this study was to evaluate the accuracy of the temperature thermistors used in the Terumo Capiox SX25 oxygenator and to compare the temperature measured at the outlet of the oxygenator using the Capiox CX*TL Luer Thermistor with temperatures measured at distal sites.
Rat Cardiopulmonary Bypass Model: Application of a Miniature Extracorporeal Circuit Composed of Asanguinous Prime
A clinically relevant rat cardiopulmonary bypass (CPB) model would be a valuable tool for investigating pathophysiological and therapeutic strategies on bypass.
Combination of Acute Preoperative Plateletpheresis, Cell Salvage, and Aprotinin Minimizes Blood Loss and Requirement During Cardiac Surgery
In this prospective randomized clinical study, the efficacy of these combined approaches on reducing blood loss and transfusion requirements was evaluated.