World's Largest Resource for Cardiovascular Perfusion

Perfusion NewswireBlood ManagementEffect of Ultrafiltration on Extravascular Lung Water Assessed by Lung Ultrasound in Children Undergoing Cardiac Surgery: A Randomized Prospective Study

Effect of Ultrafiltration on Extravascular Lung Water Assessed by Lung Ultrasound in Children Undergoing Cardiac Surgery: A Randomized Prospective Study

BACKGROUND:

Increased lung water and the resultant atelectasis are significant pulmonary complications after cardiopulmonary bypass (CPB) in children undergoing cardiac surgery; these complications are observed after CPB than after anaesthesia alone. Ultrafiltration has been shown to decrease total body water and postoperative blood loss and improve the alveolar to arterial oxygen gradient and pulmonary compliance. This study investigated whether conventional ultrafiltration during CPB in paediatric heart surgeries influences post-bypass extravascular lung water (EVLW) assessed by lung ultrasound (LUS).

METHODS:

This randomized controlled study included 60 patients with congenital heart disease (ASA II-III), aged 1 to 48 months, with a body weight > 3 kg. Conventional ultrafiltration targeting a haematocrit (HCT) level of 28% was performed on the ultrafiltration group, while the control group did not receive ultrafiltration. LUS scores were recorded at baseline and at the end of surgery. The PaO2/FiO2 ratio (arterial oxygen tension divided by the fraction of inspired oxygen), urine output, and haemodynamic parameters were also recorded.

RESULTS:

LUS scores were comparable between the two groups both at baseline (p = 0.92) and at the end of surgery (p = 0.95); however, within the same group, the scores at the end of surgery significantly differed from their baseline values in both the ultrafiltration (p = 0.01) and non-ultrafiltration groups (p = 0.02). The baseline PaO2/FiO2 ratio was comparable between both groups. at the end of surgery, The PaO2/FiO2 ratio increased in the ultrafiltration group compared to that in the non-ultrafiltration group, albeit insignificant (p = 0.16). no correlation between the PaO2/FiO2 ratio and LUS score was found at baseline (r = - 0.21, p = 0.31). On the other hand, post-surgicalmeasurements were negatively correlated (r = - 0.41, p = 0.045).

CONCLUSION:

Conventional ultrafiltration did not alter the EVLW when assessed by LUS and oxygenation state. Similarly, ultrafiltration did not affect the urea and creatinine levels, intensive care unit (ICU) stays, ventilation days, or mortality.


Leave a Reply

#1 largest online community of Perfusionists

Join Our Perfusion.com
Online Community

Get your swag kit by becoming a member or updating profile.
Swag will be sent to U.S. mailing addresses only.
©2024 Perfusion. All Rights Reserved. Privacy Policy | Your Privacy Choices