World's Largest Resource for Cardiovascular Perfusion

Perfusion NewswireMain ZoneLevosimendan versus an Intra-Aortic Balloon Pump in High-Risk Cardiac Patients

Levosimendan versus an Intra-Aortic Balloon Pump in High-Risk Cardiac Patients


OBJECTIVE:


To test the hypothesis that levosimendan is more effective than intra-aortic balloon pump (IABP) support in cardiac surgical patients with low left ventricular ejection fraction to decrease cardiac troponin I levels (primary endpoint) and improve hemodynamics.


DESIGN:


Prospective randomized trial.


SETTING:


Tertiary cardiothoracic referral center.


PARTICIPANTS:


Ninety patients with coronary artery disease and left ventricular ejection fraction <35% who underwent surgery with cardiopulmonary bypass.


INTERVENTION:


Patients were assigned randomly to 1 of 3 groups. Group A received a prophylactic IABP one day before surgery. Group B received a prophylactic IABP one day before surgery and a levosimendan infusion at a dose of 0.1 μg/kg/min with an initial bolus (12 μg/kg for 10 minutes) after anesthesia induction. Group C received a levosimendan infusion at a dose of 0.1 μg/kg/min with an initial bolus (12 μg/kg for 10 minutes) after anesthesia induction. Hemodynamic and biochemical data and rate of complications were analyzed.


MEASUREMENTS AND MAIN RESULTS:


The cardiac troponin I level in group C 6 hours after surgery was lower than in group A (p = 0.048). The cardiac index in group A was significantly lower than in groups B and C. The intensive care unit stay was significantly shorter in group C than in groups A and B (p = 0.001). The need for inotropic support, the rate of complications, and mortality among groups did not differ.


CONCLUSIONS:


The infusion of levosimendan after anesthesia induction in cardiac surgical patients contributes to lower cardiac troponin I levels and improved hemodynamics compared with a preoperative IABP.


Leave a Reply