Perfusion NewswireMain ZoneEffects of Cell Saver Autologous Blood Transfusion on Blood Loss and Homologous Blood Transfusion Requirements in Patients Undergoing Cardiac Surgery

Effects of Cell Saver Autologous Blood Transfusion on Blood Loss and Homologous Blood Transfusion Requirements in Patients Undergoing Cardiac Surgery

Objective: Off-pump CABG is potentially associated with reduced intraoperative blood loss and homologous blood transfusion in comparison to on-pump CABG. In this randomised controlled study we investigated the effects of autologous cell saver blood transfusion on blood loss and homologous blood transfusion requirements in patients undergoing CABG on- versus off-CPB.


Methods: Eighty patients were randomised into one of four groups: (A) on-CPB with cell saver blood transfusion (CSBT), (B) on-CPB without CSBT, (C) off-pump with CSBT and (D) off-pump without CSBT. Volume of intraoperative autologous blood transfusion, postoperative mediastinal blood loss and homologous blood transfusion requirements were measured. Homologous blood was transfused when haemoglobin concentration fell below 8g/dl postoperatively. Pre- and postoperatively prothrombin time and partial thromboplastin time were measured.


Results: Preoperative patient characteristics were well matched among the four groups. The amount of salvaged mediastinal blood available for autologous transfusion was significantly higher in the on-pump group (A) compared to the off-CPB group (C) (433+/-155ml vs 271+/-144ml, P=0.001). Volume of homologous blood transfusion was significantly higher in group B vs groups A, C and D (595+/-438ml vs 179+/-214, 141+/-183 and 230+/-240ml, respectively, P<0.005). The cell saver groups (A and C) received significantly less homologous blood than the groups without cell saver (160+/-197ml vs 413+/-394ml, respectively, P<0.005). Patients undergoing off-CPB surgery received significantly less homologous blood than those undergoing on-CPB CABG irrespective of cell saver blood transfusion (184+/-214ml vs 382+/-397ml, P<0.05). Postoperative blood loss was similar in the four groups (842+/-276, 1023+/-291, 869+/-286 and 903+/-315ml in groups A to D, respectively, P>0.05). Clotting test results revealed no significant difference between the groups. There was no significant difference in postoperative morbidity between groups.


Conclusion: Off-pump CABG is associated with significant reduction in intraoperative mediastinal blood loss and homologous transfusion requirements. Autologous transfusion of salvaged washed mediastinal blood reduced homologous transfusion significantly in the on-CPB group. Cell saver caused no significant adverse impact on coagulation parameters in on- or off-CPB CABG. Postoperative morbidity and blood loss were not affected by the use of CPB or autologous blood transfusion. We recommend the use of autologous blood transfusion in both on- and off-pump CABG surgery.